Systems coveredOne- and two-component cementitious waterproofingPolymer-modified flexible coatings and crack bridgingWet areas, foundations, terraces and poolsCompatibility of primers, mesh and successive coats
Formulation approachSelect polymer type and dosage against flexibility and cost targetsTest capillary absorption, adhesion and resistance to water pressureOptimise filler distribution, rheology and film formationAssess packaging, storage and application-temperature risks
Technical package deliveredApplication-specific formula and component alternativesTest methods and performance acceptance criteriaSurface preparation and application procedureRoot-cause and corrective-action plan for field failures